Hurricane™ Haze 2D User Manual Rev. 12 Page 7 of 16
This product can work with an input voltage of either 120 VAC, 60 Hz or
230 VAC, 50 Hz depending on the model.
To determine the power requirements for a particular product, see the label affixed to
the back plate of the product or refer to the product’s specifications chart. The listed
current rating indicates the product’s average current draw under normal conditions.
Always connect this product to a protected circuit
(circuit breaker or fuse),
making sure that it has
an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to
a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Disconnect this product from the power outlet before replacing the fuse.
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse out of the housing.
3. Remove the blown fuse from the holder and replace
same type and rating.
4. Insert the fuse holder back in place and reconnect power.
The product does not ship with a spare fuse; however, the safety cap has room
for a spare.
Spare fuse holder
(inside safety cap)
Installed fuse (held
by plastic clip)